American Academy of Periodontology Journal of Periodontology Online Welcome Guest
Sign in | Register
 
Abstract
2007, Vol. 78, No. 5, Pages 879-888 , DOI 10.1902/jop.2007.060280
(doi:10.1902/jop.2007.060280)

Influence of Different Implant Surfaces on Peri-Implant Osteogenesis: Histomorphometric Analysis in Sheep

Marco Franchi,* Beatrice Bacchelli,* Gianluca Giavaresi, Viviana De Pasquale,* Désirée Martini,* Milena Fini, Roberto Giardino, and Alessandro Ruggeri*

*Department of Human Anatomical Sciences and Physiopathology of Locomotory Apparatus, University of Bologna, Bologna, Italy.

†Department of Experimental Surgery, Codivilla-Putti Research Institute, Rizzoli Orthopedic Institute, Bologna, Italy.

Correspondence: Dr. Marco Franchi, Human Anatomy Institute, Via Irnerio 48, 140126 Bologna, Italy. Fax: 39-051-2091659; e-mail: .

Background: The present study investigated peri-implant osteogenesis and implant biologic fixation in different zirconia sandblasted endosseous titanium surfaces (SLA-60 and SLA-120) and a turned titanium surface (T) 2 and 4 weeks after surgery.

Methods: Seventy-two implant screws were implanted in tibia of six sheep. Histologic sections of implants (2 and 4 weeks after surgery) were analyzed with light microscopy for histomorphometric analysis of bone-to-implant contact (BIC), bone ingrowth (BI), and bone surface (BS/BV). Histologic blocks were used to perform bone microhardness studies next to the implants. Some implants were also observed with scanning electron microscopy (SEM) and transmission electron microscopy (TEM).

Results: In general, the highest values of BIC, BI, BS/BV, and Vickers hardness number (HV) were measured in SLA-60 samples, followed by SLA-120 and T implants. Two weeks after surgery, all the implants appeared biologically fixed by a newly formed woven bone arranged in thin bone trabeculae and filling the gap between implant and host bone. Four weeks after implantation, the thickness of the woven bone trabeculae had increased, especially around the SLA-60 and SLA-120 implants by a gradual deposition of parallel-fiber bone.

Conclusions: Our results suggest that, in the early period of peri-implant healing, the implant surface morphology that seemed to influence the increase of peri-implant osteogenesis, bone turnover, and peri-implant bone maturation was SLA-60. We suggest that this surface, characterized by moderately deep titanium cavities very similar to the osteocyte lacunae, could act as a microscopic scaffold for mesenchymal and/or osteoblast-like cells adhesion.

KEYWORDS: Dental implantation, endosseous, histology, microscopy, electron, osseointegration, titanium, zirconium oxide

Full Text PDF (22,863.626 KB) PDF Plus (601.979 KB)
 

Previous Article | Next Article
View/Print PDF (22864 KB)
View PDF Plus (602 KB)
Add to favorites
Email to a friend
TOC Alert | Citation Alert What is RSS?

 
 
Quick Search
for 
Authors:
Marco Franchi
Beatrice Bacchelli
Gianluca Giavaresi
Viviana De Pasquale
Désirée Martini
Milena Fini
Roberto Giardino
Alessandro Ruggeri
Keywords:
Dental implantation, endosseous
histology
microscopy, electron
osseointegration
titanium
zirconium oxide

© 2009 American Academy of Periodontology. All rights reserved.
Disclaimers apply | Privacy commitment | Contact AAP
Technology Partner - Atypon Systems, Inc.