Abstract
July 2005, Vol. 76, No. 7, Pages 1092-1099
, DOI 10.1902/jop.2005.76.7.1092
(doi:10.1902/jop.2005.76.7.1092)
Analysis of Failed Commercially Pure Titanium Dental Implants: A Scanning Electron Microscopy and Energy-Dispersive Spectrometer X-Ray Study Dr. Jamil Awad ShibliDental Research Division, Department of Periodontology, Guarulhos University, Guarulhos, SP, Brazil. Elcio MarcantonioDepartment of Oral and Maxillofacial Surgery, Dental School of Araraquara, State University of Sao Paulo (UNESP), Araraquara, SP, Brazil. Susana d'AvilaDepartment of Dental Materials and Prosthodontics, Dental School of Araraquara, State University of Sao Paulo (UNESP). Antonio Carlos GuastaldiDepartment of Physic-Chemistry, Institute of Chemistry, State University of Sao Paulo (UNESP). Elcio Marcantonio Jr.Department of Periodontology, Dental School of Araraquara, State University of Sao Paulo (UNESP). Background: The failure of osseointegration in oral rehabilitation has gained importance in current literature and in clinical practice. The integration of titanium dental implants in alveolar bone has been partly ascribed to the biocompatibility of the implant surface oxide layer. The aim of this investigation was to analyze the surface topography and composition of failed titanium dental implants in order to determine possible causes of failure. Methods: Twenty-one commercially pure titanium (cpTi) implants were retrieved from 16 patients (mean age of 50.33 ± 11.81 years). Fourteen implants were retrieved before loading (early failures), six after loading (late failures), and one because of mandibular canal damage. The failure criterion was lack of osseointegration characterized as dental implant mobility. Two unused implants were used as a control group. All implant surfaces were examined by scanning electron microscopy (SEM) and energy-dispersive spectrometer x-ray (EDS) to element analysis. Evaluations were performed on several locations of the same implant. Results: SEM showed that the surface of all retrieved implants consisted of different degrees of organic residues, appearing mainly as dark stains. The surface topography presented as grooves and ridges along the machined surface similar to control group. Overall, foreign elements such as carbon, oxygen, sodium, calcium, silicon, and aluminum were detected in failed implants. The implants from control group presented no macroscopic contamination and clear signs of titanium. Conclusion: These preliminary results do not suggest any material-related cause for implant failures, although different element composition was assessed between failed implants and control implants. J Periodontol 2005;76:1092-1099. KEYWORDS: Comparison studies , dental implants, failure , microscopy, electron, scanning , osseointegration , peri-implant diseases , titanium , x-rays, spectrometry, energy-dispersive Cited byJamil A. Shibli, Leandro Melo, Daniel S. Ferrari, Luciene C. Figueiredo, Marcelo Faveri, Magda Feres. (2008) Composition of supra- and subgingival biofilm of subjects with healthy and diseased implants. Clinical Oral Implants Research 19:10, 975-982 Online publication date: 1-Nov-2008. CrossRef Garrit Koller, Richard J. Cook, Ian D. Thompson, Timothy F. Watson, Lucy Silvio. (2007) Surface modification of titanium implants using bioactive glasses with air abrasion technologies. Journal of Materials Science Materials in Medicine 18:12, 2291 CrossRef
|
|
|