American Academy of Periodontology Journal of Periodontology Online Welcome Guest
Sign in | Register
 
Abstract
July 2005, Vol. 76, No. 7, Pages 1066-1071 , DOI 10.1902/jop.2005.76.7.1066
(doi:10.1902/jop.2005.76.7.1066)

Resonance Frequency Analysis of One- Stage Dental Implant Stability During the Osseointegration Period

S. Ersanli

Department of Oral Implantology, School of Dentistry, Istanbul University, Istanbul, Turkey.

C. Karabuda

Department of Oral Implantology, School of Dentistry, Istanbul University, Istanbul, Turkey.

F. Beck

Section of Oral Biology, College of Dentistry, The Ohio State University, Columbus, OH.

Dr. B. Leblebicioglu

Currently, Section of Periodontology, College of Dentistry, The Ohio State University; previously, Department of Oral Implantology, Istanbul University, School of Dentistry.

Background: Currently, there is no available clinical tool to evaluate the amount of osseointegration and stability around dental implants. It has been recently suggested that changes in the stiffness of an implant in bone during healing may be monitored by using resonance frequency analysis (RFA). The aim of this study was to determine whether RFA can be integrated into the routine clinical evaluation of initial healing of dental implants.

Methods: Thirty-one patients (18 female and 13 male; mean age of 51.7 years) were included into this study. A total of 122 implants and three different, but comparable, implant designs were evaluated by using RFA. The specific transducer for each implant system was used. ISQ (implant stability quotient) readings were obtained for each implant at the time of surgery, 3 and 6 weeks postoperatively, and at the time of loading (3 or 6 months following surgery). Data were analyzed for different healing times, various anatomical locations, implant length, and type. Average time in function was 12 months.

Results: Two implants failed during healing. Implant stability was higher on the mandible compared to the maxilla for each implant system studied (Mann-Whitney test, P <0.01). ISQ readings decreased significantly at 3 and 6 weeks post-surgery compared to readings obtained at surgery (Wilcoxon matched pairs sign-rank tests, P <0.01). A recovery to the initial ISQ levels was noted at the time of implant loading. The possible effects of different types and lengths of implants to ISQ readings were examined.

Conclusions: Results of this study support the need for a clinical tool to evaluate dental implant stability prior to loading, especially for implants placed in the maxilla. It appears that implant stability is weakest at 3 to 6 weeks in one-stage non-loaded dental implants. ISQ readings can be used to determine different healing phases and the stability of dental implants. However, it is difficult to define a general standardized range of ISQ readings for successful implant integration for various implant systems. Thus, RFA values/ISQ levels should be calibrated for each implant system separately. Further studies are needed to compare the early changes seen in immediately loaded dental implants and to determine whether there is any time in which the total recovery in ISQ levels may occur. J Periodontol 2005;76:1066-1071.

KEYWORDS: Alveolar bone loss/therapy , bone and bones , dental implantation, immediate , osseointegration , resonance frequency analysis

Cited by

, , , . (2009) Assessment of dental implant stability in osseodistraction-generated bone: a resonance frequency analysis. Clinical Oral Implants Research
Online publication date: 1-May-2009.
CrossRef
, , . (2009) Implant stability in relation to osseointegration: an experimental study in the Labrador dog. Clinical Oral Implants Research 20:3, 313-318
Online publication date: 1-Apr-2009.
CrossRef
, , , . (2008) Parameters of resonance frequency measurement values: a retrospective study of 385 ITI dental implants. Clinical Oral Implants Research 19:2, 214-218
Online publication date: 1-Mar-2008.
CrossRef
, , , , , , , . (2008) Implant stability during osseointegration in irradiated and non-irradiated minipig alveolar bone: an experimental study. Clinical Oral Implants Research 19:2, 201-206
Online publication date: 1-Mar-2008.
CrossRef
, , , , , . (2008) Multivariate study of factors influencing primary dental implant stability. Clinical Oral Implants Research 19:2, 196-200
Online publication date: 1-Mar-2008.
CrossRef
, , , , . (2007) A biomechanical assessment of the relation between the oral implant stability at insertion and subjective bone quality assessment. Journal Of Clinical Periodontology 34:4, 359
CrossRef
, , . (2007) Clinical study on the primary stability of two dental implant systems with resonance frequency analysis. Clinical Oral Investigations 11:3, 257
CrossRef
. (2006) A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Brnemark system implants. Journal of Oral Rehabilitation 33:10, 754
CrossRef
, , , . (2006) Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement. Journal of Oral Rehabilitation 33:12, 881
CrossRef
, , , , . (2006) Correlation Between Implant Stability Quotient and Bone-Implant Contact: A Retrospective Histological and Histomorphometrical Study of Seven Titanium Implants Retrieved from Humans. Clinical Implant Dentistry and Related Research 8:4, 218
CrossRef
PDF (397.593 KB) PDF Plus (252.852 KB)
 

Previous Article | Next Article
View/Print PDF (398 KB)
View PDF Plus (253 KB)
Add to favorites
Email to a friend
TOC Alert | Citation Alert What is RSS?

 
 
Quick Search
for 
Authors:
S. Ersanli
C. Karabuda
F. Beck
Dr. B. Leblebicioglu
Keywords:
Alveolar bone loss/therapy
bone and bones
dental implantation, immediate
osseointegration
resonance frequency analysis

© 2009 American Academy of Periodontology. All rights reserved.